Diverter Damper for Gas Turbines Type UK
The UK type diverter for gas turbine systems is a cost-efficient alternative to a small toggle arm driven diverters. The pivot driven unit requires less space and provides minimum pressure loss in both directions.
![]() | ![]() | |
Function:
- Diverts the gas turbine exhaust gas to the HRSG or to the bypass stack
- 100 % flue gas tight sealing with seal air
Advantages:
- Open/close and fast emergency closing duty
- Very low pressure drop in each direction
- Short delivery times
Parameters:
| Size: | up to 20 m² |
| Temperature: | up to 670 °C |
| Pressure: | up to 100 mbar |
| Materials: | carbon steels, stainless steels |
| Actuation: | electric, pneumatic or hydraulic |
| Insulation: | internal (standard), external |
Further diverters: